Skip to main content
QMSQMS
QMS
  • Welcome to your QMS
  • Quality Manual
  • Procedures
  • Records
  • Legit.Health Plus Version 1.1.0.0
    • Index of Technical Documentation or Product File
    • Summary of Technical Documentation (STED)
    • Description and specifications
    • R-TF-001-007 Declaration of conformity
    • GSPR
    • Clinical
    • Design and development
    • Design History File
      • Requirements
        • PRS
        • Deprecated Software Requirement Specification (SRS)
        • Software Requirement Specification (SRS)
          • SRS-001: Generate Automatic PASI (APASI) severity analysis report for single zone
          • SRS-002: Generate Automatic SCORAD (ASCORAD) severity analysis report for single zone
          • SRS-003: Generate Automatic Urticaria Activity Score (AUAS) report for single zone
          • SRS-004: Generate Automatic GPPGA (AGPPGA) report for single zone
          • SRS-005: Generate Automatic IHS4 (AIHS4) report for single zone
          • SRS-006: Generate ALADIN Score report for single zone
          • SRS-007: Generate Automatic VASI (AVASI) report for single zone
          • SRS-008: Generate Automatic AWOSI report for single zone
          • SRS-009: Generate Automatic NSIL report for single zone
          • SRS-010: Generate Automatic SALT (ASALT) report for single zone
          • SRS-011: Generate Automatic EASI (AEASI) report for single zone
          • SRS-012: Orchestrate severity analysis workflow
          • SRS-013 Generate an aggregated ICD probability distribution from image set
          • SRS-014 Generate per-image ICD analysis with explainability heat map
          • SRS-015 Generate an unified report of ICD class distributions
          • SRS-016: Include model sensitivity in report
          • SRS-017: Include model specificity in report
          • SRS-018: Include entropy score in report
          • SRS-019: Include the indicator of having a condition in the report
          • SRS-020: Include the indicator of the image presenting a pigmented lesion in the report
          • SRS-021: Include the indicator of malignancy in the report
          • SRS-022: Include the indicator of needing an urgent referral in the report
          • SRS-023: Include the indicator of needing a high priority referral in the report
          • SRS-024 The product validates the image with the AI LABS's Dermatological Image Quality Assessment (DIQA) algorithm
          • SRS-025 The product validates the image's clinical domain
          • SRS-026 The product classifies the image's modality
          • SRS-027 The product provides a final image validity summary
          • SRS-028: Orchestrate diagnosis support workflow
          • SRS-029: Compute 7-Point Checklist (7PC) Score
          • SRS-030: Compute Dermatology Life Quality Index (DLQI) Score
          • SRS-031: Compute PURE-4 Score
          • SRS-032: Compute Urticaria Control Test (UCT) Score
          • SRS-033: Calculate Global Acne Grading System (GAGS) Score
          • SRS-034: Calculate RESVECH Score
          • SRS-035: Calculate SCOVID Score
          • SRS-036: Calculate Physician's Global Assessment (PGA) Score
          • SRS-037: Generate Global Automatic VASI (AVASI) Score for Full Body
          • SRS-038: Secure Communication Protocol Enforcement
          • SRS-039: Network Service Exposure
          • SRS-040: URL-Based API Versioning
          • SRS-041: Concurrent API Version Support
          • SRS-042: JSON Data Interchange Format
          • SRS-043: Endpoint Implementation
          • SRS-044: Deterministic Response Schemas
          • SRS-045: Performance and Latency
          • SRS-046: Standard HTTP Status Code Usage
          • SRS-047: Endpoint Access Control
          • SRS-048: API Documentation Endpoint
          • SRS-049: High Availability and Load Balancing Support
          • SRS-050: Provision of Client SDKs for Integration
          • SRS-051: API Rate Limiting
          • SRS-052: Request Body Size Limitation
          • SRS-053: Provision of Clinical Parameter Endpoints
          • SRS-054: API Health Check Endpoint
        • missing-documents
      • Test plans
      • Test runs
      • Review meetings
      • 🥣 SOUPs
      • REL-001 Version 1.1.0.0
    • IFU and label
    • Post-Market Surveillance
    • Quality control
    • Risk Management
    • Usability and Human Factors Engineering
  • Legit.Health Plus Version 1.1.0.1
  • Licenses and accreditations
  • External documentation
  • Public tenders
  • Legit.Health Plus Version 1.1.0.0
  • Design History File
  • Requirements
  • Software Requirement Specification (SRS)
  • SRS-029: Compute 7-Point Checklist (7PC) Score

SRS-029: Compute 7-Point Checklist (7PC) Score

Identifier​

SRS-029

Software System​

  • Processor
  • Report Builder
  • Orchestrator

Category​

  • Functional

Description​

Upon a user-initiated request to perform a 7-Point Checklist (7PC) assessment, the system shall calculate a risk score based on user-provided answers. The system shall perform the following integrated actions:

  1. Parse user input: The system parses the user's answer ("Yes" or "No") for each of the seven checklist items (e.g., Change in Size, Irregular Pigmentation, Irregular Border).
  2. Calculate score: The system shall calculate the final, composite 7PC score by summing the points associated with the user's answers.
  3. Assemble report: Generate and display a structured report that consolidates the assessment results. The report shall contain the following clearly labelled data points:
    • The final 7PC score and its corresponding risk interpretation (e.g., "High risk").
    • A list of all seven checklist items and the corresponding answer provided by the user.

Derived from PRS​

  • PRS-002: Measure severity by combining image analysis and user-reported symptoms in scoring systems
Previous
SRS-028: Orchestrate diagnosis support workflow
Next
SRS-030: Compute Dermatology Life Quality Index (DLQI) Score
  • Identifier
  • Software System
  • Category
  • Description
  • Derived from PRS
All the information contained in this QMS is confidential. The recipient agrees not to transmit or reproduce the information, neither by himself nor by third parties, through whichever means, without obtaining the prior written permission of Legit.Health (AI LABS GROUP S.L.)